@ -7,15 +7,15 @@ namespace InverterMon.Server.InverterService;
sealed class SettingsData
{
public double BatteryCutOffVoltage { get; set; }
public double BatteryCvChargingVoltage { get; set; }
public double BatteryFloatingChargingVoltage { get; set; }
public double BatteryBackToChargeVoltage { get; set; }
public double BatteryBackToDischargeVoltage { get; set; }
public byte OutputSourcePriority { get; set; }
public byte ChargingSourcePriority { get; set; }
public byte MaxChargingCurrent { get; set; }
public byte MaxAcChargingCurrent { get; set; }
public double BatteryCutOffVoltage { get; init; }
public double BatteryCvChargingVoltage { get; init; }
public double BatteryFloatingChargingVoltage { get; init; }
public double BatteryBackToChargeVoltage { get; init; }
public double BatteryBackToDischargeVoltage { get; init; }
public byte OutputSourcePriority { get; init; }
public byte ChargingSourcePriority { get; init; }
public byte MaxChargingCurrent { get; init; }
public byte MaxAcChargingCurrent { get; init; }
}
[SuppressMessage("Performance", "CA1822:Mark members as static"),
@ -119,54 +119,15 @@ public sealed class FelicitySolarInverter
internal void SetSetting(Setting setting, double value)
{
ushort registerAddress;
switch (setting)
value *= setting switch
{
case Setting.DischargeCutOff:
registerAddress = 0x211F;
value *= 10; // scale volts to register value
break;
case Setting.BulkVoltage:
registerAddress = 0x2122;
value *= 10;
break;
case Setting.FloatVoltage:
registerAddress = 0x2123;
value *= 10;
break;
case Setting.BackToGrid:
registerAddress = 0x2156;
value *= 10;
break;
case Setting.BackToBattery:
registerAddress = 0x2159;
value *= 10;
break;
case Setting.OutputPriority:
registerAddress = 0x212A; // No scaling needed for priority values (0,1,2 etc.)
break;
case Setting.ChargePriority:
registerAddress = 0x212C;
break;
case Setting.CombinedChargeCurrent:
registerAddress = 0x212E; // Value in amperes (1A per unit)
break;
case Setting.UtilityChargeCurrent:
registerAddress = 0x2130;
break;
default:
throw new ArgumentException("Invalid setting!");
}
Setting.DischargeCutOff or
Setting.BulkVoltage or
Setting.FloatVoltage or
Setting.BackToGrid or
Setting.BackToBattery => 10,
_ => throw new ArgumentException("Invalid setting!")
};
var settingValue = (ushort)value;
@ -176,8 +137,8 @@ public sealed class FelicitySolarInverter
var frame = new byte[8];
frame[0] = SlaveAddress;
frame[1] = 0x06;
frame[2] = (byte)(registerAddress >> 8);
frame[3] = (byte)(registerAddress & 0xFF);
frame[2] = (byte)((ushort)setting >> 8);
frame[3] = (byte)((ushort)setting & 0xFF);
frame[4] = (byte)(settingValue >> 8);
frame[5] = (byte)(settingValue & 0xFF);
var crc = CalculateCrc(frame, 6);

View File

@ -1,16 +1,16 @@
namespace InverterMon.Shared.Models;
public enum Setting
public enum Setting : ushort
{
ChargePriority = 1,
OutputPriority = 2,
CombinedChargeCurrent = 3,
UtilityChargeCurrent = 4,
BulkVoltage = 5,
FloatVoltage = 6,
DischargeCutOff = 7,
BackToGrid = 8,
BackToBattery = 9
ChargePriority = 0x212C,
OutputPriority = 0x212A,
CombinedChargeCurrent = 0x212E,
UtilityChargeCurrent = 0x2130,
BulkVoltage = 0x2122,
FloatVoltage = 0x2123,
DischargeCutOff = 0x211F,
BackToGrid = 0x2156,
BackToBattery = 0x2159
}
public enum WorkingMode : short